• Users Online: 29
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2020  |  Volume : 5  |  Issue : 1  |  Page : 39-46

Radiation dose measurements in intraoral and panoramic dental radiography in the Southern Region of Saudi Arabia


1 Department of Radiological Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia
2 Department of Radiological Sciences, Applied Medical Sciences College, Najran University, Najran, Saudi Arabia
3 Radiology Department, KMGH, Khamis Mushayt, Saudi Arabia
4 Department of Radiological Science, Colleges of Applied Medical Sciences, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
5 Department of Diagnostic Sciences & Oral Biology, College of Dentistry, King Khalid University, Abha, Saudi Arabia
6 Departments of Pediatric Dentistry and Orthodontic Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
7 Diagnostic radiology department, Applied Medical Sciences College, Jazan University, Saudi Arabia

Correspondence Address:
Mohammed S Alqahtani
Department of Radiological Sciences College of Applied Medical Sciences King Khalid University, Abha
Saudi Arabia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/WKMP-0204.291958

Rights and Permissions

Objective: This study aims to estimate patient radiation doses for intraoral and panoramic dental radiography in the southern region of Saudi Arabia. Material and Methods: For intraoral units, the radiation doses were measured in terms of incident air kerma, Ki, and the detector was placed at 50 cm from the focus point. For panoramic dental radiography, the radiation doses were measured in terms of air Kerma-area product, PKA, using a calibrated CT ionization chamber. Results: For intraoral, the values for the estimated incidence of air kerma, Ki, ranged from 1.25 to 4.61 mGy (average: 2.55 mGy). For panoramic, the values for estimated Kerma-area product, PKA, values ranged from 79.5 to 122.1 mGy.cm2 (average: 99 mGy.cm2) for adults and ranged from 43.3 to 80.2 mGy.cm2 (average: 58.5mGy.cm2) for paediatrics. Conclusion: The study’s outcomes were compared with previous studies from other countries, indicating similar or slightly higher values. These results could serve as baseline data for radiation protection optimization and the development of national diagnostic reference levels in Saudi Arabia.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed99    
    Printed14    
    Emailed0    
    PDF Downloaded18    
    Comments [Add]    

Recommend this journal